tamamaryland.blogg.se

Rigol wfm file converter
Rigol wfm file converter





rigol wfm file converter

Once the Refresh button is enabled the data column updates periodically. The Refresh button on this screen, toggles data transfer on and off. Once the Scope is connected and the appropriate Resource selected, it's time to Add a New Data Tab. Highlight the Tools Menu and Click the Connect to Oscilloscope Prompt If multiple drivers are on the computer, you'll want to select the USB Resource. Ultrascope can be downloaded from and opens like: In order to start the data transfer between the scope and the computer, Ultrascope needs to be connected to the computer. Ultrascope Rigol's virtual oscilloscope application, Ultrascope, provides a method of importing scope screens to a computer and potentially to an Excel spreadsheet. This note describes a method to capture averaged waveforms from either the E or D series when they are connected to a computer with the USB bus. Note: The averaging capability is available when the sweep time is 20 ms or less! Unlike the DS1000CB and DS1000B series, the DS1000E, and the D1000D Series will only write the most recently acquired waveform to the front panel USB stick. This feature provides an opportunity to study the signal of interest without the distraction of other signals. RIGOL’s UltraScope works with Series D/E Rigol scopes can be configured to display the result of averaging several (as many as 256) waveforms. How To Acquire Average waveforms from DS1000 Scopes Related to these models or series: D1000B/CA/D/E Series B and CA include the ability in the firmware. You may need to do a number of receives to get all the data from the buffe

rigol wfm file converter

OPTION: It may be useful to use the Single Trigger mode by sending “:TRIG:SING:MODE” instead of then sending STOP. Once you have capture your waveform, continue to step 4.Ĥ. Send “:RUN” to acquire waveform of interest. Here is the command set to return 1M points from channel 1ġNOTE: It may be helpful to insert a wait or sleep between commands to prevent communications errors. To return more points, you will need to operate the scope in “:STOP” mode. NOTE: The first time you run the “:WAVE:DATA?” command, you will return 600 points. Where can be CHAN1, CHAN2, DIG (For D series only), MATH, or FFT Where can be NORM, RAW, or MAX See table 1 below for data points returned in each mode.ģ. For actual data depth, see Table 1 below.

rigol wfm file converter

There are some conventions that need to be established: Here are the commands and proper order for remote retrieval of the data over USB. The DS1000E/D series of oscilloscopes from Rigol can download captured waveforms containing up to 1 million data points.







Rigol wfm file converter